CNT RESEARCH undertake testing of Transformer Oil, Power Transformers, Current Transformers, Potential Transformers, Residual Voltage Transformers, Current Limiting Reactors, EHT SF6 Breakers, HT SF6 Breakers, HT VCB Breakers, HT OCB Breakers, HT RMU Breakers, HT Breaker Protection Relays, LT ACB Breakers and LT OCB Breakers.

Testing of Transformer Oil
❖ Electrical Properties Analysis
✦ Dielectric Strength Test
✦ Dielectric Dissipation Factor Test
✦ Specific Resistance Test
❖ Chemical Properties Analysis
✦ Neutralization Value Test
✦ Water Content Test
✦ Sediments & Sludge Test
❖ Physical Properties Analysis
✦ Physical condition & Appearance Test
✦ Density Test
✦ Flash Point Test
✦ Inter Facial Tension Test
✦ Kinematic Viscosity Test
✦ Pour Point Test
❖ Power Transformer Internal Fault Analysis
✦ Dissolved Gases Analysis (DGA)
★ Total Dissolved Combustible Gas
★ Concentration of component gases
⚬ Hydrogen H2
⚬ Oxygen O2
⚬ Nitrogen N2
⚬ Carbon Monoxide CO
⚬ Carbon Dioxide CO2
⚬ Methane CH4
⚬ Ethane C2H6
⚬ Ethylene C2H4
⚬ Acetyline C2H2
⚬ Propane C3H8
⚬ Propylene C3H6
❖ Power Transformer Remnant Life Assessment
✦ FURAN Analysis
✦ 2,6-di-tert-Butyl p-Cresol (DBPC) Analysis &
2,6-di-tert-Butyl Phenol (DBP) Analysis
❖ Transformer Oil Remnant Life Assessment
✦ Polychlorinated Biphenlyls (PCB's) Analysis
✦ Corrosive Sulphur Test
✦ Oxidation Stability
Testing of EHV Power Transformer
❖ Insulation Condition Analysis
✦ Insulation Resistance & Polarization Index Test
✦ Dissipation Factor (Tan δ) Test of Insulation Capacitance
✦ Capacitance Test
✦ Induced High Voltage Test
✦ Power Frequency High Voltage Test
✦ Double Frequency High Voltage Test
❖ Winding Condition Analysis
✦ HV Winding Resistance Test at 75℃
✦ LV Winding Resistance Test at 75℃
✦ Thermography Test
❖ Core-Coil Assembly Condition Analysis
✦ Verification of Terminals & Polarity Test
✦ Magnetic Balance Test
✦ Magnetization Current Test
✦ No Load Loss Test
✦ No Load Current Test
✦ No Load Current Harmonics Test
✦ Full Load Loss Test
✦ Short-Circuit Impedance Test
✦ Zero-Sequence Impedance Test
✦ Ratio Test on all tap position
✦ Vector Group Test
✦ Sweep Frequency Response Analysis Test
✦ Sound Level Test
❖ On-load Tap-Changer Assembly Condition Analysis
✦ Operation Test
✦ Auxiliary Circuit Insulation Test
❖ EHV Condenser Bushing Condition Analysis
✦ Partial Discharge Test
❖ Control Simulation Analysis
✦ MOG Operation Test
✦ Buchholz Relay Operation Test
✦ OSR Operation Test
✦ PRD Test Operation Test (Main tank)
✦ PRD Test Operation Test (OLTC tank)
✦ OTI Calibration Test
✦ WTI Calibration Test
❖ Earthing Pit Analysis
✦ Earth Resistance Test
Testing of Current Transformer
❖ Insulation Condition Analysis
✦ Insulation Resistance Test
✦ Tan Delta (Tan δ) & Capacitance Test
✦ Overvoltage Interturn Test
✦ Power Frequency High Voltage Test
✦ Double Frequency High Voltage Test
❖ Winding Condition Analysis
✦ Primary Winding Resistance Test at 75℃
✦ Secondary Winding Resistance Test at 75℃
✦ Thermography Test
❖ Core-Coil Assembly Condition Analysis
✦ Verification of Terminals & Polarity Test
✦ Magnetization Curve Test
✦ Knee Point Voltage Test
✦ Composite Error Test
✦ Ratio Error Test
✦ Phase Angle Error Test
✦ Temperature Rise Test
Testing of Potential Transformer
❖ Insulation Condition Analysis
✦ Insulation Resistance Test
✦ Capacitance & Tan Delta (Tan δ) Test
✦ Induced High Voltage Test
✦ Power Frequency High Voltage Test
✦ Double Frequency High Voltage Test
❖ Winding Condition Analysis
✦ Primary Winding Resistance Test at 75℃
✦ Secondary Winding Resistance Test at 75℃
✦ Thermography Test
❖ Core-Coil Assembly Condition Analysis
✦ Verification of Terminals & Polarity Test
✦ Ratio Error Test
✦ Phase Angle Error Test
✦ Temperature Rise Test
Testing of Residual Voltage Transformer
❖ Insulation Condition Analysis
✦ Insulation Resistance Test
✦ Capacitance & Tan Delta (Tan δ) Test
✦ Induced High Voltage Test
✦ Power Frequency High Voltage Test
✦ Double Frequency High Voltage Test
❖ Winding Condition Analysis
✦ Primary Winding Resistance Test at 75℃
✦ Secondary Winding Resistance Test at 75℃
✦ Thermography Test
❖ Core-Coil Assembly Condition Analysis
✦ Verification of Terminals & Polarity Test
✦ Open Delta Test
✦ Ratio Error Test
✦ Phase Angle Error Test
✦ Temperature Rise Test
Testing of Current Limiting Reactor
❖ Insulation Condition Analysis
✦ Insulation Resistance Test
✦ Capacitance & Tan Delta (Tan δ) Test
✦ Power Frequency High Voltage Test
✦ Double Frequency High Voltage Test
❖ Winding Condition Analysis
✦ Winding Resistance Test at 75℃
✦ Thermography Test
❖ Coil Assembly Condition Analysis
✦ Reactance Test
✦ Temperature Rise Test
✦ Full Load Loss Test
✦ Short-Circuit Impedance Test
Testing of EHT & HT SF6 Circuit Breaker
❖ Insulation Condition Analysis
✦ Insulation Resistance Test
✦ Power Frequency High Voltage Test
❖ Contacts Condition Analysis
✦ Contact Resistance Test at 75℃
✦ Thermography Test
❖ Triping Coil Condition Analysis
✦ Relay Test
✦ Alarm Test
✦ Triping Test
❖ Triping CT Condition Analysis
✦ Insulation Resistance Test
✦ Primary Current Injection Test
✦ Overvoltage Interturn Test
✦ Power Frequency High Voltage Test
✦ Secondary Winding Resistance Test at 75℃
✦ Current Ratio Test
Testing of HT Vaccum Circuit Breaker
❖ Insulation Condition Analysis
✦ Insulation Resistance Test
✦ Power Frequency High Voltage Test
❖ Contacts Condition Analysis
✦ Contact Resistance Test at 75℃
✦ Thermography Test
❖ Triping Coil Condition Analysis
✦ Relay Test
✦ Alarm Test
✦ Triping Test
❖ Triping CT Condition Analysis
✦ Insulation Resistance Test
✦ Primary Current Injection Test
✦ Overvoltage Interturn Test
✦ Power Frequency High Voltage Test
✦ Secondary Winding Resistance Test at 75℃
✦ Current Ratio Test
Testing of HT Oil Circuit Breaker
❖ Insulation Condition Analysis
✦ Dielectric strength Test
✦ Insulation Resistance Test
✦ Power Frequency High Voltage Test
❖ Contacts Condition Analysis
✦ Contact Resistance Test at 75℃
✦ Thermography Test
❖ Triping Coil Condition Analysis
✦ Relay Test
✦ Alarm Test
✦ Triping Test
❖ Triping CT Condition Analysis
✦ Insulation Resistance Test
✦ Primary Current Injection Test
✦ Overvoltage Interturn Test
✦ Power Frequency High Voltage Test
✦ Secondary Winding Resistance Test at 75℃
✦ Current Ratio Test
Testing of HT Ring Main Unit Breaker
❖ Insulation Condition Analysis
✦ Dielectric strength Test
✦ Insulation Resistance Test
✦ Power Frequency High Voltage Test
❖ Contacts Condition Analysis
✦ Contact Resistance Test at 75℃
✦ Thermography Test
❖ Triping Coil Condition Analysis
✦ Relay Test
✦ Alarm Test
✦ Triping Test
❖ Triping CT Condition Analysis
✦ Insulation Resistance Test
✦ Primary Current Injection Test
✦ Overvoltage Interturn Test
✦ Power Frequency High Voltage Test
✦ Secondary Winding Resistance Test at 75℃
✦ Current Ratio Test
Testing LT Oil Circuit Breaker
❖ Insulation Condition Analysis
✦ Dielectric strength Test
✦ Insulation Resistance Test
✦ Power Frequency High Voltage Test
❖ Contacts Condition Analysis
✦ Contact Resistance Test at 75℃
✦ Thermography Test
❖ Triping Coil Condition Analysis
✦ Relay Test
✦ Alarm Test
✦ Triping Test
❖ Triping CT Condition Analysis
✦ Insulation Resistance Test
✦ Primary Current Injection Test
✦ Overvoltage Interturn Test
✦ Power Frequency High Voltage Test
✦ Secondary Winding Resistance Test at 75℃
✦ Current Ratio Test
Testing LT Air Circuit Breaker
❖ Insulation Condition Analysis
✦ Insulation Resistance Test
✦ Power Frequency High Voltage Test
❖ Contacts Condition Analysis
✦ Contact Resistance Test at 75℃
✦ Thermography Test
❖ Triping Coil Condition Analysis
✦ Relay Test
✦ Alarm Test
✦ Triping Test
❖ Triping CT Condition Analysis
✦ Insulation Resistance Test
✦ Primary Current Injection Test
✦ Overvoltage Interturn Test
✦ Power Frequency High Voltage Test
✦ Secondary Winding Resistance Test at 75℃
✦ Current Ratio Test
Testing of Protection Relays
❖ Power Transformer Primary Winding Phase to Phase Fault Analysis
✦ Differential Protection Relay Test
☆ Current Differential Protection Relay Test
✦ Overcurrent Protection Relay Test
☆ Instantaneous Over Current (IOC) Protection Relay Test
☆ Definite Time Over Current (DTOC) Protection Relay Test
☆ Inverse Time Over Current (ITOC) Protection Relay Test
☆ Inverse Definite Minimum Time (IDMT) Protection Relay Test
❖ Power Transformer Primary Winding Phase to Earth Fault Analysis
✦ Differential Protection Relay Test
✦ Overcurrent Protection Relay Test
☆ Instantaneous Over Current (IOC) Protection Relay Test
☆ Definite Time Over Current (DTOC) Protection Relay Test
☆ Inverse Time Over Current (ITOC) Protection Relay Test
☆ Inverse Definite Minimum Time (IDMT) Protection Relay Test
☆ Induction Disc Over Current Protection Relay Test
❖ Power Transformer Secondary Winding Phase to Phase Fault Analysis
✦ Differential Protection Relay Test
❖ Power Transformer Secondary Winding Phase to Earth Fault Analysis
✦ Differential Protection Relay Test
✦ Restricted Earth Fault Relay Test
❖ Power Transformer Winding Interturn Fault Analysis
✦ Differential Protection Relay Test
✦ Buchholz Gas Protection Relay Test
❖ Power Transformer Core Flashover Arcing Fault Analysis
✦ Differential Protection Relay Test
✦ Buchholz Gas Protection Relay Test
❖ Power Transformer Oil Tank Flashover Arcing Fault Analysis
✦ Differential Protection Relay Test
✦ Buchholz Gas Protection Relay Test
✦ Earth Resistance Test
❖ Power Transformer Overfluxing Fault Analysis
✦ Overfluxing Protection Test
❖ Power Transformer Overheating Fault Analysis
✦ Overheating Thermography Test
❖ High Voltage Transmission Line Fault Analysis
✦ Distance Protection Relay Test
✦ Directional Protection Relay Test
❖ Parallel Grid Supply Fault Analysis
✦ Synchronism Protection Relay Test
Customer
CNT RESEARCH B2B customers are listed public and private limited companies across India.
Tushar Shinde is the founder, promoter and CEO of CNT RESEARCH established in year 2004.
Contact us
✆ 9321690034
✆ 9320690034
✆ 9820690034
✉ cnt@cnt.org.in
www.cnt.org.in
Tushar Shinde
CEO
CNT RESEARCH
Registered Address :
202, Rachana Apartment, Anand Nagar
Kulgaon, Badlapur (E)
Thane - 421503
Maharashtra
India
Marketing Office :
B/402, Lotus Corporate Park
Laxmi Nagar, Goregaon (E)
Mumbai - 400063
Maharashtra
India
Regional Office :
Masat Industrial Area
Silvassa Vapi Road
Samarvarni, Silvassa
Dadra & Nagar Haveli - 396230
Dadra & Nagar Haveli & Daman and Diu
India
Regional Office :
Pithampur Industrial Area
Mhow Nimach Road
Akolia, Pithampur
Dhar - 454775
Madhya Pradesh
India